24/7 Emergency: 07414 254125
REFCOM · F-Gas Certified
Wall-mounted split air conditioning indoor unit in a commercial office

AC Faults

AC Icing Up in London & the M25

Ice forms on an indoor coil when the coil runs colder than freezing. That reduces airflow further, so the problem gets worse until cooling stops or water leaks as it thaws. Ice is a sign of an airflow, charge or control fault.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

Early signs of icing

Icing usually starts small: frost on the small pipe at the outdoor unit, a thin layer on part of the indoor coil or water dripping after the unit stops. Catching it early — before it blocks the coil — usually means a simpler fix, such as cleaning filters or restoring airflow.

Clean, repair or recharge

If airflow is the cause, cleaning and fan repair solve it. If charge is low, the leak has to be found and repaired before gas is added — topping up alone means the ice will return. Agree that order of work in the quote.

What makes a coil freeze

Blocked filters, a dirty coil, a slow or failed indoor fan, a closed or blocked return path, low refrigerant charge and very low set points on a cool day are the usual causes. On multi-unit systems an expansion valve fault on one unit can freeze that unit alone.

Other guides on ac indoor coil icing or freezing up

Common questions on ac indoor coil icing or freezing up are answered on the AC Frozen page.

Choosing the right visit

Describe the equipment and what you need — a repair, a service, an inspection or a quote for new equipment — so the visit is scoped correctly and the right engineer attends.

  • The outcome you need from the visit
  • Equipment details and access
  • How findings will be reported

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.

How each type of visit works and all rates · What to have ready when you book · How we work