AC Faults
AC Icing Up in London & the M25
Ice forms on an indoor coil when the coil runs colder than freezing. That reduces airflow further, so the problem gets worse until cooling stops or water leaks as it thaws. Ice is a sign of an airflow, charge or control fault.
Early signs of icing
Icing usually starts small: frost on the small pipe at the outdoor unit, a thin layer on part of the indoor coil or water dripping after the unit stops. Catching it early — before it blocks the coil — usually means a simpler fix, such as cleaning filters or restoring airflow.
Clean, repair or recharge
If airflow is the cause, cleaning and fan repair solve it. If charge is low, the leak has to be found and repaired before gas is added — topping up alone means the ice will return. Agree that order of work in the quote.
What makes a coil freeze
Blocked filters, a dirty coil, a slow or failed indoor fan, a closed or blocked return path, low refrigerant charge and very low set points on a cool day are the usual causes. On multi-unit systems an expansion valve fault on one unit can freeze that unit alone.
Choosing the right visit
Describe the equipment and what you need — a repair, a service, an inspection or a quote for new equipment — so the visit is scoped correctly and the right engineer attends.