Manufacturers require regular servicing to keep warranties valid; F-Gas regulations require routine leak checks on systems above set thresholds. Our PPM contracts wrap both into one scheduled visit, with full digital reports and a maintained F-Gas logbook.
Commercial air conditioning servicing — what we cover
Quarterly or biannual visits
Schedules from once a year for small systems up to quarterly for kitchens, server rooms and 24/7 sites.
Filter & coil cleaning
Indoor filter wash/replace, evaporator coil clean and condenser fin straightening.
Drain & condensate checks
Pan flush, drain line test and condensate pump function check.
F-Gas leak testing & logbook
Statutory leak checks for systems above 5 tCO2e, with logbook entries and EA-compliant records.
Controls & BMS health check
Schedule verification, sensor calibration, BMS point review.
Reduced labour rates
Contract sites get priority response and discounted hourly rates on out-of-scope work.
Frequently asked questions
London Locations Covered
Agreeing planned maintenance
A maintenance visit records condition and performance. Faults found are reported and quoted separately unless your contract says otherwise. Agree the asset list and visit frequency first.
- Which assets are included
- Tasks per visit and the report format
- How faults found are authorised
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted. Contracts are quoted per asset list and visit interval.
How each type of visit works and all rates · What to have ready when you book · How we work
AC Maintenance & Service: scope, checks and next steps
How to separate the possible causes and decide between repair and replacement is covered on the main commercial air conditioning page.
What each check helps establish
- Quarterly, bi-annual or annual service visits
- Agree the interval against manufacturer guidance, operating hours and equipment condition rather than assuming one schedule suits every asset.
- Filter clean & deep evaporator hygiene clean
- Filter condition can restrict airflow; cleaning and replacement requirements depend on the filter specification.
- Refrigerant pressure & superheat checks
- Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
- Drain pan, pump and condensate line clear
- Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.