Air Conditioning Heat Pumps — Commercial HVAC services

Air Conditioning

Air Conditioning Heat Pumps

Air-to-air heat pump systems deliver efficient heating in winter and cooling in summer — ideal where gas boilers aren't practical or where you want one system for both seasons.

Wall-mounted split air conditioning indoor unit in a commercial office — Air Conditioning Heat Pumps by londonhvacpro
Walk-in cold room interior with stainless shelving and evaporator unit — Air Conditioning Heat Pumps by londonhvacpro
HVAC engineer’s refrigeration gauges, vacuum pump and hand tools on a workbench — Air Conditioning Heat Pumps by londonhvacpro

Modern inverter heat pumps deliver 3–4 kW of heat for every 1 kW of electricity. We design and install reverse-cycle split, multi-split and VRF heat pump systems for homes, offices and retail across London and the M25 — and service any brand.

What we cover

Reverse-cycle split & multi-split

Wall, cassette and ducted units delivering both heating and cooling from one outdoor unit.

VRF heat pump & heat recovery

Multi-zone VRF with simultaneous heating and cooling on different floors or zones.

Replacing electric heaters

Direct swap-outs for electric panel and storage heaters — slashing running costs.

Low-temperature winter performance

Selection of units rated for full output down to -15°C or lower for UK winters.

Smart controls & scheduling

App control, weekly schedules and integration with BMS or smart-home systems.

Service & repair

PPM and emergency repair for existing heat-pump AC systems regardless of brand.

Brands we service

Mitsubishi Electric Zubadan · Daikin Bluevolution · Toshiba · LG · Panasonic

Frequently asked questions

A reverse-cycle AC unit IS an air-to-air heat pump — the same hardware moves heat both ways. We just emphasise the heating mode for buildings using AC as their primary winter heat.

Typical seasonal COP is 3.5–4.5, meaning you get 3.5–4.5 kW of heat per 1 kW of electricity drawn. Much cheaper to run than direct electric heating.

Yes. Modern inverter heat pumps deliver rated output down to -15°C or lower; cold-climate models go further.

Modern outdoor units run at 45–55 dB at 1 m — quieter than a fridge. Positioning matters; we advise during the survey.

London Locations Covered

Air Conditioning in CamdenAir Conditioning in WestminsterAir Conditioning in IslingtonAir Conditioning in HackneyAir Conditioning in SouthwarkAir Conditioning in LambethAir Conditioning in Tower HamletsAir Conditioning in WandsworthAir Conditioning in Hammersmith and FulhamAir Conditioning in Kensington and ChelseaAir Conditioning in GreenwichAir Conditioning in LewishamAir Conditioning in BrentAir Conditioning in EalingAir Conditioning in HaringeyAir Conditioning in NewhamAir Conditioning in BarnetAir Conditioning in EnfieldAir Conditioning in CroydonAir Conditioning in BromleyAir Conditioning in Richmond upon ThamesAir Conditioning in Kingston upon ThamesAir Conditioning in HounslowAir Conditioning in Merton

Choosing the right visit

Describe the equipment and what you need — a repair, a service, an inspection or a quote for new equipment — so the visit is scoped correctly and the right engineer attends.

  • The outcome you need from the visit
  • Equipment details and access
  • How findings will be reported

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and materials are quoted in writing before they are fitted.

How each type of visit works and all rates · What to have ready when you book · How we work

Air Conditioning Heat Pumps: scope, checks and next steps

Reverse-cycle AC changes between heating and cooling; output depends on operating conditions. Defrost behaviour in heating mode is not automatically a breakdown.

Separate the possible causes

Compare selected mode, indoor airflow, outdoor conditions, fault codes and the length of heating interruptions. Separate normal defrost from repeated lockouts or prolonged loss of heat.

Repair or replacement?

Component repair and a change in heating duty are different decisions. Replacement needs a heat-load assessment and a check of performance at the conditions the building actually experiences.

What each check helps establish

Split & multi-split reverse-cycle heat pumps
Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
VRF heat-recovery systems (simultaneous heat & cool)
Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
Low-ambient kits for reliable winter heating
Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
COP-optimised system sizing and zoning
Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.

Details to include with your job request

Provide indoor and outdoor model numbers, mode settings and when heat stops. Explain whether every room or only one zone is affected.