If your AC is blowing warm, leaking water, throwing error codes or simply won't start, we diagnose and fix it — usually on the first visit. We carry common boards, capacitors, sensors and refrigerant for all major brands.
Commercial Air Conditioning Repair in London
Commercial air conditioning repair is our core day-to-day work. When cooling fails in an office, shop, restaurant, hotel or server room, it costs you staff comfort, customer footfall and sometimes stock or equipment. Our F-Gas certified engineers attend commercial sites across London and the M25, diagnose the fault with pressure, temperature and electrical readings, and fix it on the first visit wherever the parts allow.
Whether you search for commercial air con repair, commercial air con repairs or commercial air conditioner repair, the work is the same: find the root cause, repair it properly and leave the system logged and running. We repair systems regardless of who installed them, and we work on all the major manufacturers, including Mitsubishi Electric, Daikin, Toshiba, LG, Fujitsu, Panasonic and Samsung.
Commercial Air Con Repairs: VRV/VRF, Splits and Chillers
VRV and VRF systems: communication and addressing errors, failed outdoor or indoor PCBs, inverter compressor faults, faulty electronic expansion valves, branch selector and BC controller faults, and refrigerant leaks across long pipe runs. We read the system fault history before we touch anything, so multi-unit faults are traced to the right component.
Split, multi-split, cassette and ducted units: no cooling or warm air, water leaking from indoor units, blocked condensate drains and failed pumps, noisy fans and compressors, capacitor and sensor failures, and frozen coils caused by low refrigerant or poor airflow.
Chillers: low and high pressure trips, flow faults, freeze protection trips, compressor failures and controls faults on air-cooled and water-cooled chillers serving fan coil and AHU systems. Leaks are traced electronically, repaired, pressure tested and recharged, with all refrigerant handling recorded under F-Gas rules.
Commercial Air Conditioner Repair Response & Maintenance Contracts
Commercial sites get same-day response, with 24/7 emergency callout when kit is down. Our rate is £120 + VAT per hour with a one-hour minimum, and any parts are quoted before they are fitted, so there are no surprises on the invoice.
Most breakdowns we attend are preventable. Once a system is repaired, we can put it on a planned preventative maintenance (PPM) contract so filters, coils, drains and refrigerant levels are checked on a schedule, reducing repeat callouts and keeping the system compliant.
What we cover
No-cooling / warm air faults
Compressor, fan, sensor and refrigerant diagnostics with on-the-spot repair where possible.
Water leaks & blocked drains
Condensate pump replacement, drain line clear-out and tray re-seating.
F-Gas leak detection & repair
Electronic leak tracing, brazing, pressure test and recharge — fully logged.
PCB & control board faults
Replacement of outdoor and indoor PCBs, IPM/inverter modules and remote controllers.
Error code diagnostics
Mitsubishi, Daikin, Toshiba and LG fault code interpretation and resolution.
Noisy / vibrating units
Compressor mounts, fan bearings, bracket isolators and pipework re-clipping.
Brands we service
Mitsubishi Electric · Daikin · Toshiba · LG · Fujitsu · Panasonic · Samsung · Sanyo
Frequently asked questions
London Locations Covered
Regional coverage and specialist services
Agreeing the repair
A repair visit starts by confirming the fault and its cause, so the part replaced is the one that failed. The repair finishes with a test under normal operating load.
- The component found at fault and why it failed
- Parts, refrigerant and lead time in writing
- The test that proves the repair worked
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.
How each type of visit works and all rates · What to have ready when you book · How we work
Air Conditioning Repair: scope, checks and next steps
How to separate the possible causes and decide between repair and replacement is covered on the main commercial air conditioning page.
What each check helps establish
- Electronic F-Gas leak detection & repair
- Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
- Refrigerant recovery and regas (R32, R410A, R407C)
- Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
- Compressor, fan motor and PCB replacement
- Operation, mechanical condition and control demand must be separated before condemning the drive.
- Condensate drain & pump fault diagnosis
- Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.