Water-cooled AC pushes the heat-rejection step to a central plant — chillers, cooling towers or a condenser-water loop — making it ideal for tall buildings, dense floorplates and projects where outdoor condenser space is limited. We service the full loop: indoor FCUs and WSHPs, pumps, valves, plant-room kit and controls.
What we cover
Fan coil units (FCUs)
Ceiling-void, exposed and cassette FCU install, service and coil cleaning.
Water source heat pumps
Console and ducted WSHPs on a shared condenser-water loop for offices and hotels.
Chilled water pipework & valves
PICVs, balancing valves, strainers, pressure-independent control valves and air vents.
Pumps & pressurisation
Circulation pump replacement, expansion vessel and pressurisation unit service.
Cooling tower service
Open-circuit and closed-circuit towers — fill cleaning, fan service, water treatment liaison.
Water treatment & dosing
Loop flush, chemical dosing and L8 sampling coordination.
Frequently asked questions
London Locations Covered
Choosing the right visit
Describe the equipment and what you need — a repair, a service, an inspection or a quote for new equipment — so the visit is scoped correctly and the right engineer attends.
- The outcome you need from the visit
- Equipment details and access
- How findings will be reported
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.
How each type of visit works and all rates · What to have ready when you book · How we work
Water Cooled AC: scope, checks and next steps
Water-cooled AC relies on a building water loop for heat rejection. The local unit and the shared loop can each cause poor performance.
Separate the possible causes
Compare loop availability, water flow, strainers, valves and unit controls before attributing the fault to the refrigeration circuit.
Repair or replacement?
Unit replacement will not solve an inadequate or unavailable shared loop. Confirm the building operator’s requirements, water conditions and available capacity before selecting equipment.
What each check helps establish
- Water-cooled VRF design & install
- Water condition, cleaning and equipment suitability should be checked against the manufacturer’s requirements.
- Cooling tower & dry cooler integration
- Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Riser pipework and pump-set installation
- Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- Water-loop balancing and commissioning
- Water condition, cleaning and equipment suitability should be checked against the manufacturer’s requirements.
Details to include with your job request
Provide the unit model, loop operating information and building-management contact. Establish who controls access to shared pumps and valves.