In cooling mode an indoor unit removes moisture from the air. That water collects in a tray and leaves by gravity or a condensate pump. Leaks happen when the water cannot get away, when it forms in the wrong place, or when ice on the coil melts faster than the tray can drain.
Where the water usually comes from
The commonest causes are a blocked tray outlet or drain pipe, a failed or air-locked condensate pump, a drain run with too little fall, a cracked tray, and a coil that iced up because of dirty filters or low airflow and then thawed. Uninsulated refrigerant pipework can also drip condensation.
How the engineer traces the leak
The engineer test-pours water into the tray and follows it to the discharge point, checks the pump float and alarm switch, inspects the fall of the drain run and looks for icing on the coil. If the coil has been icing, airflow and refrigerant temperatures are measured to find out why.