AC Refrigerant
AC Recharge in London & the M25
A sealed system should not lose refrigerant. If a recharge is needed, refrigerant has escaped somewhere, and adding gas without finding the leak only delays the next failure and releases more refrigerant.
If your AC has lost its charge
Losing charge always means a leak. Signs include weak cooling, ice on the small pipe at the outdoor unit, longer run times and hissing at joints. Topping up without finding the leak means paying again later and releasing more refrigerant. Ask for the leak location and repair to be included in the quote.
What a proper recharge involves
Locating the leak, repairing it, pressure testing with nitrogen, evacuating the circuit and then weighing in the correct charge from the rating plate and pipe length calculation, with a record of the refrigerant added.
Why a “top-up” is not a repair
Adding refrigerant to a leaking system breaches the purpose of the F-Gas rules on leak repair and leaves the fault in place. Systems with charges above the threshold must also have the leak repaired and rechecked within a month.
Other guides on ac refrigerant recharge and top-up
AC refrigerant recharge and top-up: questions
Choosing the right visit
Describe the equipment and what you need — a repair, a service, an inspection or a quote for new equipment — so the visit is scoped correctly and the right engineer attends.
- The outcome you need from the visit
- Equipment details and access
- How findings will be reported
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.