Refrigeration Faults
Evaporator Icing in London & the M25
The evaporator absorbs heat from the cooled space. Its fan, coil condition and defrost system decide how evenly a cabinet or room cools and how much ice builds up.
Heavy icing
Defrost heaters or terminations that have failed, door seals letting moist air in, drain lines that freeze and refreeze, and low airflow all produce ice that insulates the coil from the air.
Repairs
Fan motor replacement, coil cleaning, defrost heater or sensor replacement, drain heater repair or, for corroded or leaking coils, coil replacement with a full pressure test.
Uneven cooling
A failed evaporator fan, a coil partly blocked by ice or dirt, damaged air guides and shelves loaded against the air path leave warm spots even when the controller shows the right temperature.
Other guides on evaporator fans, coils and icing
Evaporator fans, coils and icing: questions
Choosing the right visit
Describe the equipment and what you need — a repair, a service, an inspection or a quote for new equipment — so the visit is scoped correctly and the right engineer attends.
- The outcome you need from the visit
- Equipment details and access
- How findings will be reported
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.
How each type of visit works and all rates · What to have ready when you book · How we work