24/7 Emergency: 07414 254125
REFCOM · F-Gas Certified
HVAC engineer’s refrigeration gauges, vacuum pump and hand tools on a workbench

AHU Services

AHU Bearing Replacement in London & the M25

AHU bearing replacement with shaft and impeller condition checked, and vibration readings taken on run-up to prove the repair.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

AHU Bearing Replacement explained

AHU bearing replacement with shaft and impeller condition checked, and vibration readings taken on run-up to prove the repair.

  • Vibration and noise assessment: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Shaft and housing condition: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Bearing replacement and greasing: Operation, mechanical condition and control demand must be separated before condemning the drive.
  • Impeller balance check: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Alignment after refit: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Run-up vibration readings: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.

Interpreting the reported fault

Inspect filters, belts or direct drives, dampers, coils and control response. Airflow limitations may be mechanical or arise from the control strategy.

  • Reported symptom: rumbling, vibration or a fan shaft that has developed play

AHU Bearing Replacement: scope and decisions

Air handling and ventilation concern delivered airflow as well as fan operation. A motor running does not establish adequate supply or extract at the occupied space.

Fan upgrades need the required duty and compatibility checked. Replacing a motor alone will not correct excessive system resistance, failed dampers or an unsuitable operating schedule.

Provide the unit model, symptoms, filter records and safe access arrangements. Explain whether the issue is noise, reduced flow, temperature or loss of extract.

Agreeing a replacement

Replacement quotes should name the new equipment or component, what is being reused and what is not, how refrigerant and old equipment are handled and how the result is commissioned.

  • Exact replacement model or part number
  • Recovery and disposal of the old equipment
  • Commissioning and handover records

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted. New equipment is a fixed written quote after a survey.