Fan Coil Unit Services

Fan Coil Unit Chilled-Water Fault in London & the M25

Diagnosis of chilled-water side faults on fan coil units, from delta T and valve operation through to riser pressure and coil insulation.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

Fan Coil Unit Chilled-Water Fault explained

Diagnosis of chilled-water side faults on fan coil units, from delta T and valve operation through to riser pressure and coil insulation.

  • Chilled flow and return temperature readings: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
  • Delta T assessment across coils: Condition and airflow affect heat transfer; look beyond surface appearance to obstruction and operating performance.
  • Cooling valve and PICV operation: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
  • Insulation and condensation review: Damage or moisture can change heat gain; assess the enclosure as well as the mechanical plant.
  • Strainer and flow verification: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
  • Pump and riser pressure checks: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
  • Findings referred back to plant where needed: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.

Interpreting the reported fault

Review alarms, flow proving, pump status, entering and leaving water conditions and condenser operation. Separate the chiller fault from distribution problems elsewhere in the building.

  • Reported symptom: chilled water units that will not pull the space temperature down

Fan Coil Unit Chilled-Water Fault: scope and decisions

A chiller serves a water circuit as well as a refrigeration circuit. Poor water flow, control demand or heat rejection can limit cooling without a compressor failure.

A plant repair needs to address the original failure conditions. Replacement sizing should use the actual cooling duty, redundancy requirements and existing water circuit—not only the old nameplate rating.

Provide the chiller model, alarm history, plant schematic where available and the effect on occupied spaces or process equipment.

Agreeing a diagnostic visit

A diagnostic visit is paid time to find the cause. Expect the readings taken and a clear statement of the fault, with any repair quoted before work continues.

  • The readings and tests to be carried out
  • A written finding
  • Repair price before further work

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.

How each type of visit works and all rates · What to have ready when you book · How we work