Fan Coil Unit Services
Fan Coil Unit Repair in London & the M25
Repair of fan coil units that have stopped running, stopped heating or cooling, become noisy or started leaking, diagnosed and fixed on the first visit where parts allow.
Fan Coil Unit Repair explained
Repair of fan coil units that have stopped running, stopped heating or cooling, become noisy or started leaking, diagnosed and fixed on the first visit where parts allow.
- On-site diagnosis and fault isolation: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Fan motor and capacitor replacement: Operation, mechanical condition and control demand must be separated before condemning the drive.
- Valve, actuator and PICV replacement: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
- Condensate pump and trap repair: Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.
- Control and sensor replacement: Compare the input reading, requested output and actual equipment response; an error code is a starting point, not a diagnosis.
- Coil leak assessment: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
- Post-repair performance test: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
Interpreting the reported fault
Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.
- Reported symptom: a unit that has stopped running, stopped conditioning or started leaking
Fan Coil Unit Repair: scope and decisions
A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.
A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.
Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.
Agreeing the repair
A repair visit starts by confirming the fault and its cause, so the part replaced is the one that failed. The repair finishes with a test under normal operating load.
- The component found at fault and why it failed
- Parts, refrigerant and lead time in writing
- The test that proves the repair worked
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.
How each type of visit works and all rates · What to have ready when you book · How we work