Fan Coil Unit Services
Fan Coil Unit Commissioning in London & the M25
Commissioning of new and replacement fan coil units, setting flow rates, fan speeds and controls to design and issuing full commissioning records.
Fan Coil Unit Commissioning explained
Commissioning of new and replacement fan coil units, setting flow rates, fan speeds and controls to design and issuing full commissioning records.
- Flow rate setting against design: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- PICV and commissioning valve setting: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
- Fan speed tap selection: Operation, mechanical condition and control demand must be separated before condemning the drive.
- Air-on and air-off verification: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Control and BMS point proving: Compare the input reading, requested output and actual equipment response; an error code is a starting point, not a diagnosis.
- Set point and dead band configuration: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Commissioning record sheets: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
Interpreting the reported fault
Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.
- Reported symptom: new or replacement units that have never been properly set up
Fan Coil Unit Commissioning: scope and decisions
A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.
A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.
Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.
Agreeing an installation
Installation quotes are only comparable when they list the same scope: equipment, pipe lengths, drains, electrical work, access, making good and commissioning. A written quote follows a site survey.
- Equipment model and positions
- Pipe, drain and electrical scope
- Commissioning, warranty registration and first service
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted. New equipment is a fixed written quote after a survey.
How each type of visit works and all rates · What to have ready when you book · How we work