24/7 Emergency: 07414 254125
REFCOM · F-Gas Certified
HVAC engineer’s refrigeration gauges, vacuum pump and hand tools on a workbench

Fan Coil Unit Services

Fan Coil Unit Replacement in London & the M25

Replacement of failed or obsolete fan coil units, including EC fan upgrades, pipework alterations, recommissioning and disposal of the old unit.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

Fan Coil Unit Replacement explained

Replacement of failed or obsolete fan coil units, including EC fan upgrades, pipework alterations, recommissioning and disposal of the old unit.

  • Like-for-like and upgrade options: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • EC fan motor upgrades for efficiency: Operation, mechanical condition and control demand must be separated before condemning the drive.
  • Pipework, valve and drain modifications: Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.
  • Ceiling access and builders work coordination: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Isolation, drain down and refill: Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.
  • Recommissioning and balancing: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Old unit removal and disposal: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.

Interpreting the reported fault

Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.

  • Reported symptom: a unit beyond economic repair, corroded or no longer supported by parts

Fan Coil Unit Replacement: scope and decisions

A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.

A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.

Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.

Agreeing a replacement

Replacement quotes should name the new equipment or component, what is being reused and what is not, how refrigerant and old equipment are handled and how the result is commissioned.

  • Exact replacement model or part number
  • Recovery and disposal of the old equipment
  • Commissioning and handover records

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted. New equipment is a fixed written quote after a survey.