Fan Coil Unit Services
Fan Coil Unit Not Heating in London & the M25
Fault finding on fan coil units that will not heat, covering LTHW flow, valves, actuators, air locks, sensors and 2-pipe changeover settings.
Fan Coil Unit Not Heating explained
Fault finding on fan coil units that will not heat, covering LTHW flow, valves, actuators, air locks, sensors and 2-pipe changeover settings.
- LTHW flow and return temperature check: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- Heating valve and actuator stroke test: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
- Strainer and flow rate verification: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- Air lock removal from the coil: Condition and airflow affect heat transfer; look beyond surface appearance to obstruction and operating performance.
- Sensor and set point verification: Compare the input reading, requested output and actual equipment response; an error code is a starting point, not a diagnosis.
- Changeover and season mode check on 2-pipe: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Output proved with air-off readings: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
Interpreting the reported fault
Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.
- Reported symptom: cold air from a unit calling for heat in winter
Fan Coil Unit Not Heating: scope and decisions
A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.
A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.
Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.
Choosing the right visit
Describe the equipment and what you need — a repair, a service, an inspection or a quote for new equipment — so the visit is scoped correctly and the right engineer attends.
- The outcome you need from the visit
- Equipment details and access
- How findings will be reported
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and materials are quoted in writing before they are fitted.
How each type of visit works and all rates · What to have ready when you book · How we work