Fan Coil Unit Services

Fan Coil Unit 2-Port Valve Replacement in London & the M25

Replacement of 2-port control valves on fan coil units, sized correctly for the coil and proved through a full open-to-close stroke test.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

Fan Coil Unit 2-Port Valve Replacement explained

Replacement of 2-port control valves on fan coil units, sized correctly for the coil and proved through a full open-to-close stroke test.

  • On/off and modulating 2-port valves: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
  • Correct Kvs sizing for the coil: Condition and airflow affect heat transfer; look beyond surface appearance to obstruction and operating performance.
  • Isolation valve and drain point check: Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.
  • Actuator mounting and stroke test: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
  • Wiring to controller or BMS: Compare the input reading, requested output and actual equipment response; an error code is a starting point, not a diagnosis.
  • Leak test after refill: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
  • Flow measurement after replacement: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.

Interpreting the reported fault

Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.

  • Reported symptom: a 2-port valve stuck open, stuck shut or passing when closed

Fan Coil Unit 2-Port Valve Replacement: scope and decisions

A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.

A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.

Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.

Agreeing a replacement

Replacement quotes should name the new equipment or component, what is being reused and what is not, how refrigerant and old equipment are handled and how the result is commissioned.

  • Exact replacement model or part number
  • Recovery and disposal of the old equipment
  • Commissioning and handover records

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and materials are quoted in writing before they are fitted. New equipment is a fixed written quote after a survey.