Fan Coil Unit Services

Fan Coil Unit 3-Port Valve Replacement in London & the M25

Replacement of 3-port diverting and mixing valves on fan coil units, with port orientation, bypass and actuator operation all proved before handover.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

Fan Coil Unit 3-Port Valve Replacement explained

Replacement of 3-port diverting and mixing valves on fan coil units, with port orientation, bypass and actuator operation all proved before handover.

  • Diverting and mixing 3-port valves: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
  • Port orientation and flow direction check: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
  • Bypass line condition check: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Actuator replacement and stroke test: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
  • Control wiring verification: Compare the input reading, requested output and actual equipment response; an error code is a starting point, not a diagnosis.
  • Refill, vent and leak test: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
  • Temperature proof at both ports: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.

Interpreting the reported fault

Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.

  • Reported symptom: a 3-port valve failing to divert, leaving the coil hot or cold permanently

Fan Coil Unit 3-Port Valve Replacement: scope and decisions

A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.

A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.

Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.

Agreeing a replacement

Replacement quotes should name the new equipment or component, what is being reused and what is not, how refrigerant and old equipment are handled and how the result is commissioned.

  • Exact replacement model or part number
  • Recovery and disposal of the old equipment
  • Commissioning and handover records

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and materials are quoted in writing before they are fitted. New equipment is a fixed written quote after a survey.