Fan Coil Unit Services

Fan Coil Unit Balancing in London & the M25

Water-side balancing of fan coil installations so every unit receives its design flow, recorded on a balancing certificate for the building file.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

Fan Coil Unit Balancing explained

Water-side balancing of fan coil installations so every unit receives its design flow, recorded on a balancing certificate for the building file.

  • System-wide flow survey: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
  • Regulating and commissioning valve setting: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
  • PICV preset adjustment: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Differential pressure measurement: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
  • Index circuit identification: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Proportional balancing across branches: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Balancing certificate with recorded flows: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.

Interpreting the reported fault

Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.

  • Reported symptom: some floors or rooms conditioned well while others never reach set point

Fan Coil Unit Balancing: scope and decisions

A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.

A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.

Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.

Choosing the right visit

Describe the equipment and what you need — a repair, a service, an inspection or a quote for new equipment — so the visit is scoped correctly and the right engineer attends.

  • The outcome you need from the visit
  • Equipment details and access
  • How findings will be reported

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.

How each type of visit works and all rates · What to have ready when you book · How we work