Fan Coil Unit Services
Fan Coil Unit Condensate Blockage in London & the M25
Clearance of blocked fan coil condensate systems — trays, traps, pipework and pumps — with the fall corrected so the blockage does not simply return.
Fan Coil Unit Condensate Blockage explained
Clearance of blocked fan coil condensate systems — trays, traps, pipework and pumps — with the fall corrected so the blockage does not simply return.
- Blockage location and clearance: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Trap, tray and pipework flush: Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.
- Pump and float chamber clean: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- Safety switch test and reset: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Pipework fall correction: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Anti-microbial dosing to prevent regrowth: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Drain flow test before leaving: Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.
Interpreting the reported fault
Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.
- Reported symptom: a tray overflowing, a safety switch tripping the unit or water marking the ceiling
Fan Coil Unit Condensate Blockage: scope and decisions
A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.
A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.
Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.
Choosing the right visit
Describe the equipment and what you need — a repair, a service, an inspection or a quote for new equipment — so the visit is scoped correctly and the right engineer attends.
- The outcome you need from the visit
- Equipment details and access
- How findings will be reported
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.
How each type of visit works and all rates · What to have ready when you book · How we work