Fan Coil Unit Services

Fan Coil Unit Controls Repair in London & the M25

Repair of fan coil control systems — controllers, interface boards, wiring and configuration — with the full heat, cool and fan sequence proved afterwards.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

Fan Coil Unit Controls Repair explained

Repair of fan coil control systems — controllers, interface boards, wiring and configuration — with the full heat, cool and fan sequence proved afterwards.

  • Controller and interface board testing: Compare the input reading, requested output and actual equipment response; an error code is a starting point, not a diagnosis.
  • Wiring, terminal and fuse checks: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Fan speed and valve output proving: Operation, mechanical condition and control demand must be separated before condemning the drive.
  • Occupancy and time schedule review: Agree the interval against manufacturer guidance, operating hours and equipment condition rather than assuming one schedule suits every asset.
  • Sensor input verification: Compare the input reading, requested output and actual equipment response; an error code is a starting point, not a diagnosis.
  • Firmware and configuration reset: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Full sequence test after repair: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.

Interpreting the reported fault

Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.

  • Reported symptom: units running at the wrong times or ignoring their set points

Fan Coil Unit Controls Repair: scope and decisions

A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.

A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.

Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.

Agreeing the repair

A repair visit starts by confirming the fault and its cause, so the part replaced is the one that failed. The repair finishes with a test under normal operating load.

  • The component found at fault and why it failed
  • Parts, refrigerant and lead time in writing
  • The test that proves the repair worked

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.

How each type of visit works and all rates · What to have ready when you book · How we work