Fan Coil Unit Services

Fan Coil Unit Low-Flow Fault in London & the M25

Investigation of low-flow faults on fan coil units — strainers, valve settings, air locks and differential pressure — with flow restored to design and recorded.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

Fan Coil Unit Low-Flow Fault explained

Investigation of low-flow faults on fan coil units — strainers, valve settings, air locks and differential pressure — with flow restored to design and recorded.

  • Flow measurement at test points: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
  • Strainer and coil blockage checks: Condition and airflow affect heat transfer; look beyond surface appearance to obstruction and operating performance.
  • PICV and regulating valve settings: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
  • Differential pressure across the unit: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
  • Air lock and venting checks: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Pump and riser pressure review: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
  • Flow restored and recorded to design: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.

Interpreting the reported fault

Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.

  • Reported symptom: poor output from a unit even though pumps and plant are running

Fan Coil Unit Low-Flow Fault: scope and decisions

A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.

A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.

Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.

Agreeing a diagnostic visit

A diagnostic visit is paid time to find the cause. Expect the readings taken and a clear statement of the fault, with any repair quoted before work continues.

  • The readings and tests to be carried out
  • A written finding
  • Repair price before further work

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.

How each type of visit works and all rates · What to have ready when you book · How we work