Fan Coil Unit Services
Fan Coil Unit PICV Replacement in London & the M25
PICV replacement on fan coil units with the flow preset to design, differential pressure verified and a commissioning record issued.
Fan Coil Unit PICV Replacement explained
PICV replacement on fan coil units with the flow preset to design, differential pressure verified and a commissioning record issued.
- PICV sizing and flow presetting: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- Frese, Belimo and Danfoss PICVs: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Differential pressure verification: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
- Strainer clean at the same time: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- Actuator refit and signal test: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
- Flow measurement at test points: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- Commissioning record for the new setting: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
Interpreting the reported fault
Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.
- Reported symptom: a unit that cannot reach temperature and a PICV that no longer holds flow
Fan Coil Unit PICV Replacement: scope and decisions
A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.
A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.
Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.
Agreeing a replacement
Replacement quotes should name the new equipment or component, what is being reused and what is not, how refrigerant and old equipment are handled and how the result is commissioned.
- Exact replacement model or part number
- Recovery and disposal of the old equipment
- Commissioning and handover records
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted. New equipment is a fixed written quote after a survey.
How each type of visit works and all rates · What to have ready when you book · How we work