Fan Coil Unit Services

Fan Coil Unit Strainer Cleaning in London & the M25

Strainer cleaning on fan coil units to restore flow through the coil, with flow measured before and after so the improvement is proven.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

Fan Coil Unit Strainer Cleaning explained

Strainer cleaning on fan coil units to restore flow through the coil, with flow measured before and after so the improvement is proven.

  • Isolation and local drain down: Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.
  • Strainer basket removal and clean: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
  • Debris and magnetite assessment: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Gasket and cap seal renewal: Closure and seal contact should be checked together; a new gasket will not correct a misaligned door.
  • Flow measurement before and after: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
  • System water quality comment: Water condition, cleaning and equipment suitability should be checked against the manufacturer’s requirements.
  • Refill, vent and leak check: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.

Interpreting the reported fault

Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.

  • Reported symptom: low flow through the coil and poor heating or cooling output

Fan Coil Unit Strainer Cleaning: scope and decisions

A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.

A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.

Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.

Agreeing planned maintenance

A maintenance visit records condition and performance. Faults found are reported and quoted separately unless your contract says otherwise. Agree the asset list and visit frequency first.

  • Which assets are included
  • Tasks per visit and the report format
  • How faults found are authorised

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted. Contracts are quoted per asset list and visit interval.

How each type of visit works and all rates · What to have ready when you book · How we work