Fan Coil Unit Services
Fan Coil Unit Strainer Cleaning in London & the M25
Strainer cleaning on fan coil units to restore flow through the coil, with flow measured before and after so the improvement is proven.
Fan Coil Unit Strainer Cleaning explained
Strainer cleaning on fan coil units to restore flow through the coil, with flow measured before and after so the improvement is proven.
- Isolation and local drain down: Confirm where condensate should discharge and whether the obstruction, pump or drainage arrangement is responsible.
- Strainer basket removal and clean: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- Debris and magnetite assessment: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
- Gasket and cap seal renewal: Closure and seal contact should be checked together; a new gasket will not correct a misaligned door.
- Flow measurement before and after: Distinguish a pump fault from air, restrictions or closed valves elsewhere in the circuit.
- System water quality comment: Water condition, cleaning and equipment suitability should be checked against the manufacturer’s requirements.
- Refill, vent and leak check: Interpret readings against operating conditions and equipment specification; do not assume a recharge is the answer.
Interpreting the reported fault
Check fan response, filter condition, valve operation, coil condition and condensate drainage. A working fan does not establish that the water coil is receiving the required flow.
- Reported symptom: low flow through the coil and poor heating or cooling output
Fan Coil Unit Strainer Cleaning: scope and decisions
A fan coil transfers heat between room air and a water coil. The fan, control valve and building water supply all affect room output.
A fan, valve actuator or controller can often be assessed independently. Whole-unit replacement also requires access, coil duty, noise and connection compatibility to be considered.
Provide the unit location, access-panel position, controller behaviour and whether neighbouring units show the same problem.
Agreeing planned maintenance
A maintenance visit records condition and performance. Faults found are reported and quoted separately unless your contract says otherwise. Agree the asset list and visit frequency first.
- Which assets are included
- Tasks per visit and the report format
- How faults found are authorised
Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted. Contracts are quoted per asset list and visit interval.
How each type of visit works and all rates · What to have ready when you book · How we work